{"id":2955,"date":"2017-12-18T06:15:02","date_gmt":"2017-12-18T06:15:02","guid":{"rendered":"http:\/\/mpml.mie.utoronto.ca\/info\/?page_id=2955"},"modified":"2026-02-08T03:57:29","modified_gmt":"2026-02-08T08:57:29","slug":"characterization-equipment","status":"publish","type":"page","link":"https:\/\/mpml.mie.utoronto.ca\/lab\/facilities\/characterization-equipment\/","title":{"rendered":"Facilities: Characterization Equipment"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2670 alignright\" src=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/Facilities-Main-Image.jpg\" alt=\"\" width=\"349\" height=\"153\" srcset=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/Facilities-Main-Image.jpg 570w, https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/Facilities-Main-Image-300x132.jpg 300w\" sizes=\"auto, (max-width: 349px) 100vw, 349px\" \/><\/p>\n<p>&nbsp;<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"5\" cellpadding=\"10\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"50%\" height=\"77\">&nbsp;<\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\">3 <strong>Foaming simulation systems with visualization<\/strong>: This system captures in situ visualization of batch foaming process.<br \/>\n<\/span><\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2677 aligncenter\" src=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_BatchFoamingSimulationSystem.jpg\" alt=\"\" width=\"450\" height=\"347\" srcset=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_BatchFoamingSimulationSystem.jpg 450w, https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_BatchFoamingSimulationSystem-300x231.jpg 300w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\">2 <strong>Magnetic suspension balances (MSB)<\/strong>: This system measures volume sorption isotherms of gas in polymer melts using the gravimetric method.<\/span><\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2678 aligncenter\" src=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_MSB.jpg\" alt=\"\" width=\"450\" height=\"342\" srcset=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_MSB.jpg 450w, https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_MSB-300x228.jpg 300w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/span><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\"><br \/>\n<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\"><strong>1 PVT measurement system<\/strong>: This system measures volume swelling and surface tension of polymer-gas mixtures at high temperatures and pressures using a pendant\/sessile drop technique.<br \/>\n<\/span><\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2679 aligncenter\" src=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_PVT.jpg\" alt=\"\" width=\"450\" height=\"352\" srcset=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_PVT.jpg 450w, https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_PVT-300x235.jpg 300w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><br \/>\n<\/span><\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\">1 <strong>Scanning electron microscopy (SEM)<\/strong>: This system captures high-quality images of internal structures of composites, blends, and foamed products at high magnifications.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2680 aligncenter\" src=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_SEM.jpg\" alt=\"\" width=\"450\" height=\"375\" srcset=\"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_SEM.jpg 450w, https:\/\/mpml.mie.utoronto.ca\/lab\/wp-content\/uploads\/facilities_SEM-300x250.jpg 300w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #666666; font-family: Century Gothic, Arial Rounded MT Bold, Times New Roman, Arial; font-size: small;\">1 hot-stage optical microscope with image processing<br \/>\n1 rotational stress rheometer<br \/>\n1 rotational strain rheometer (ARES)<br \/>\n1 on-line slit rheological die 2 melt flow indexers<br \/>\n1 high-pressure differential scanning calorimetry (DSC) and 2 regular DSC<br \/>\n1 thermal mechanical analyzer<br \/>\n1 dynamic mechanical analyzer<br \/>\n1 3D Modeler rapid prototyping machine<br \/>\n1 microsopy image processing system<br \/>\n1 surface roughness tester<br \/>\n1 thermal gravimetric analyzer 3 pycnometers<br \/>\n1 density measuring device<br \/>\n1 Instron micro-mechanical tester<br \/>\n1 Instron drop weight impact test machine<\/span><\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\n<h4 style=\"text-align: center;\"><a href=\"https:\/\/mpml.mie.utoronto.ca\/lab\/facilities\/\">Back to the Facilities page&#8230;<\/a><\/h4>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; &nbsp; 3 Foaming simulation systems with visualization: This system captures in situ visualization of batch foaming process. &nbsp; 2 Magnetic suspension balances (MSB): This system measures volume sorption isotherms of gas in polymer melts using the gravimetric method. &nbsp; 1 PVT measurement system: This system measures volume swelling and surface tension of polymer-gas mixtures at high temperatures and pressures using a pendant\/sessile drop technique. 1 Scanning electron microscopy (SEM):&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2669,"menu_order":20,"comment_status":"closed","ping_status":"closed","template":"full-width-page.php","meta":{"footnotes":""},"class_list":["post-2955","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/pages\/2955","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/comments?post=2955"}],"version-history":[{"count":13,"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/pages\/2955\/revisions"}],"predecessor-version":[{"id":4127,"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/pages\/2955\/revisions\/4127"}],"up":[{"embeddable":true,"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/pages\/2669"}],"wp:attachment":[{"href":"https:\/\/mpml.mie.utoronto.ca\/lab\/wp-json\/wp\/v2\/media?parent=2955"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}